Review Article

Air pollution by BTEX and the related health risks due to the tobacco smoke, a systematic review

Abstract

BTEX is a group of hazardous chemical compounds that include benzene, toluene, ethylbenzene, and xylene. The indoor concentration of BTEX is mostly influenced by tobacco smoking, the region within the house, and seasonal variations. This study included three databases: "Google Scholar", "Science Direct", and "Springer". Out of the 1351 articles obtained from the keyword search, only 13 were eventually selected for this study. The most abundant compound found in houses among BTEX was toluene, with a concentration of 13.80±16.50 µg/m3. The results indicated that the concentration of benzene in houses where smoking occurred was greater than in houses where no smoking occurred (7.17±9.42 vs. 2.65±3.77 µg/m3, unpaired Wilcoxon test: p>0.05). The concentration of BTEX in houses was substantially lower than that in cafes (21.10±31.10 vs. 15,100±9740 µg/m3, unpaired Wilcoxon test: p<0.05). The urban region had the most significant accumulation of all BTEX chemicals, with the industrial and rural sectors following suit. The findings indicated that the average levels of BTEX in warm months (such as spring and summer) were higher than in cold months (such as fall and winter) within houses (28.50±44.30 vs. 8.60±7.77 µg/m3, unpaired Wilcoxon test: p > 0.05). The findings indicated that the cancer risk (CR) associated with houses (3.11×10-6) and cafes (3.54×10-3) exceeded the permissible threshold. Moreover, the waterpipe cafes that utilized fruit-flavored tobacco had the greatest CR (4.98×10-3). Furthermore, the presence of smoking, regional factors, and seasonal variations did not result in an increase in the hazard quotient (HQ) in houses beyond the acceptable thresholds.

Carlsen L, Bruggemann R, Kenessov B. Use of partial order in environmental pollution studies demonstrated by urban
TEX air pollution in 20 major cities worldwide. Science of the total environment. 2018;610:234-43.
2. Petry T, Vitale D, Joachim FJ, Smith B, Cruse L, Mascarenhas R, et al. Human health risk evaluation of selected VOC, SVOC and particulate emissions from scented candles. Regulatory Toxicology and Pharmacology. 2014;69(1):55-70.
3. Harrad S, Hazrati S, Ibarra C. Concentrations of polychlorinated biphenyls in indoor air and polybrominated diphenyl ethers in indoor air and dust in Birmingham, United Kingdom: implications for human exposure. Environmental science & technology. 2006;40(15):4633-8.
4. Mitchell CS, Zhang J, Sigsgaard T, Jantunen M, Lioy PJ, Samson R, Karol MH. Current state of the science: health effects and indoor environmental quality. Environmental health perspectives. 2007;115(6):958-64.
5. Hoffman SJ, Tan C. Overview of systematic reviews on the health-related effects of government tobacco control policies. BMC public health. 2015;15:1-11.
6. Rodgman A, Perfetti TA. The chemical components of tobacco and tobacco smoke: CRC press; 2008.
7. United States. Public Health Service. Office of the Surgeon General. The health consequences of involuntary exposure to tobacco smoke: a report of the Surgeon General. US Department of Health and Human Services, Public Health Service, Office of the Surgeon General; 2006.
8. Hazrati S, Rostami R, Fazlzadeh M. BTEX in indoor air of waterpipe cafés: Levels and factors influencing their concentrations. Science of the total environment. 2015;524:347-53.
9. El-Hashemy MA, Ali HM. Characterization of BTEX group of VOCs and inhalation risks in indoor microenvironments at small enterprises. Science of the Total Environment. 2018;645:974-83.
10. Saxena P, Ghosh C. A review of assessment of benzene, toluene, ethylbenzene and xylene (BTEX) concentration in urban atmosphere of Delhi. International Journal of the physical Sciences. 2012;7(6):850-60.
11. Fustinoni S, Campo L, Satta G, Campagna M, Ibba A, Tocco MG, et al. Environmental and lifestyle factors affect benzene uptake biomonitoring of residents near a petrochemical plant. Environment international. 2012;39(1):2-7.
12. Yadav J, Reddy C. Degradation of benzene, toluene, ethylbenzene, and xylenes (BTEX) by the lignin-degrading basidiomycete Phanerochaete chrysosporium. Applied and environmental microbiology. 1993;59(3):756-62.
13. Organization Wh, Cancer IAfRo, Humans IWGotEoCRt. IARC monographs on the evaluation of carcinogenic risks to humans: World Health Organization; 2004.
14. Momen A, Rostami R. The heavy metals in human body fluids related to the tobacco smoke: a systematic review. Tobacco and Health. 2023;2(1):15-22.
15. Hazrati S, Rostami R, Fazlzadeh M. BTEX in indoor air of waterpipe cafés: Levels and factors influencing their concentrations. Science of The Total Environment. 2015;524-525:347-53.
16. Héroux M-E, Clark N, Van Ryswyk K, Mallick R, Gilbert NL, Harrison I, et al. Predictors of indoor air concentrations in smoking and non-smoking residences. International journal of environmental research and public health. 2010;7(8):3080-99.
17. Chin JY, Godwin C, Parker E, Robins T, Lewis T, Harbin P, Batterman S. Levels and sources of volatile organic compounds in homes of children with asthma. Indoor air. 2014;24(4):403-15.
18. Villanueva F, Tapia A, Lara S, Amo-Salas M. Indoor and outdoor air concentrations of volatile organic compounds and NO2 in schools of urban, industrial and rural areas in Central-Southern Spain. Science of the Total Environment. 2018;622:222-35.
19. Van Drooge BL, Marco E, Perez N, Grimalt JO. Influence of electronic cigarette vaping on the composition of indoor organic pollutants, particles, and exhaled breath of bystanders. Environmental Science and Pollution Research. 2019;26:4654-66.
20. Heydari G, Ranjbar Vakilabadi D, Kermani M, Rayani M, Poureshgh Y, Behroozi M, et al. Load characteristics and inhalation risk assessment of benzene series (BTEX) pollutant in indoor air of Ghalyan and/or cigarette cafes compared to smoking-free cafes. Environmental Pollutants and Bioavailability. 2020;32(1):26-35.
21. Tirler W, Settimo G. Incense, sparklers and cigarettes are significant contributors to indoor benzene and particle levels. SciELO Public Health; 2015. p. 28-33.
22. Xu J, Szyszkowicz M, Jovic B, Cakmak S, Austin CC, Zhu J. Estimation of indoor and outdoor ratios of selected volatile organic compounds in Canada. Atmospheric environment. 2016;141:523-31.
23. Su F-C, Mukherjee B, Batterman S. Determinants of personal, indoor and outdoor VOC concentrations: an analysis of the RIOPA data. Environmental research. 2013;126:192-203.
24. Villanueva F, Tapia A, Amo-Salas M, Notario A, Cabanas B, Martínez E. Levels and sources of volatile organic compounds including carbonyls in indoor air of homes of Puertollano, the most industrialized city in central Iberian Peninsula. Estimation of health risk. International journal of hygiene and environmental health. 2015;218(6):522-34.
25. Charles SM, Jia C, Batterman SA, Godwin C. VOC and particulate emissions from commercial cigarettes: analysis of 2, 5-DMF as an ETS tracer. Environmental science & technology. 2008;42(4):1324-31.
26. Hazrati S, Rostami R, Farjaminezhad M, Fazlzadeh M. Preliminary assessment of BTEX concentrations in indoor air of residential buildings and atmospheric ambient air in Ardabil, Iran. Atmospheric environment. 2016;132:91-7.
Files
IssueVol 9 No 3 (2024): Summer 2024 QRcode
SectionReview Article(s)
DOI https://doi.org/10.18502/japh.v9i3.16682
Keywords
BTEX (Benzene toluene ethylbenzene xylene); Indoor air quality; Smoking; Cigarette; Health risk

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.