Original Research

Indoor air quality assessment of an existing apartment located in Indian tropical city, Bhubaneswar

Abstract

Introduction: A proper investigation on indoor pollution level in economical apartments is important, where the provision for ventilation is limited. A series of experiments were conducted in the houses within an existing economical apartment in Bhubaneswar, India to evaluate various pollutant levels.
Materials and methods: Temperature, relative humidity, CO, CO2, Particulate Matter (PM10 and PM2.5), Formaldehyde and Total volatile organic compounds in the bedrooms and kitchens are measured by pollution meters. The experiments were conducted with doors and windows closed conditions.  The readings were taken on a four consecutive working day in February 2023 at an interval of 3 h (9:00 am to 9:00 pm).
Results: The day wise temperature and humidity variations inside the bedroom and kitchen shows a reverse trend. At the afternoon, the indoor temperature becomes high, while during the night time humidity becomes the highest. The day wise indoor CO2 and CO variation trend is pretty similar. Both CO2 and CO concentrations in bedrooms are the highest in the evening. In contrast to that CO2 and CO concentrations in kitchens becomes maximum during noon time. High particulate matter concentration at outdoor and indoor is observed at the evening time. Higher formaldehyde (HCHO) and Total Volatile Organic Compounds (TVOCs) concentration at the indoor is observed at noon and afternoon time.
Conclusion: The results obtained were compared with the recommended values of World Health Organization (WHO) and National Ambient Air Quality Standards (NAQIS). The results revealed that all measured parameters are at a higher level than the recommended values except the indoor CO2 concentrations.

1. Saad SM, Shakaff AY, Saad AR, Yusof AM, Andrew AM, Zakaria A, et al. Development of indoor environmental index: Air quality index and thermal comfort index. InAIP Conference Proceedings 2017 Mar 13 (Vol. 1808, No. 1). AIP Publishing.
2. Bruce N, Pope D, Rehfuess E, Balakrishnan K, Adair-Rohani H, Dora C. WHO indoor air quality guidelines on household fuel combustion: Strategy implications of new evidence on interventions and exposure–risk functions. J Atmospheric Environment. 2015;106:451-7.
3. Pillarisetti A, Ye W, Chowdhury S. Indoor air pollution and health: Bridging perspectives from developing and developed countries. J Annual Review of Environment Resources. 2022;47:197-229.
4. Maung TZ, Bishop JE, Holt E, Turner AM, Pfrang C. Indoor air pollution and the health of vulnerable groups: a systematic review focused on particulate matter (PM), volatile organic compounds (VOCs) and their effects on children and people with pre-existing lung disease. J International Journal of Environmental Research Public Health. 2022;19(14):8752.
5. Wong NH, Huang B. Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore. J Building Environment. 2004;39(9):1115-23.
6. Muelas Á, Remacha P, Pina A, Tizné E, El-Kadmiri S, Ruiz A, et al. Analysis of different ventilation strategies and CO2 distribution in a naturally ventilated classroom. J Atmospheric Environment. 2022;283:119176.
7. Zhu J, Newhook R, Marro L, Chan CC. Selected volatile organic compounds in residential air in the city of Ottawa, Canada. J Environmental science technology. 2005;39(11):3964-71.
8. Ohura T, Amagai T, Shen X, Li S, Zhang P, Zhu L. Comparative study on indoor air quality in Japan and China: Characteristics of residential indoor and outdoor VOCs. J Atmospheric Environment. 2009;43(40):6352-9.
9. Park S, Kagi N, Umishio W, Hasegawa K, Mitamura T, Tamura J. VOC concentrations in houses in Japan: correlations with housing characteristics and types of ventilation. J Journal of Asian Architecture Building Engineering. 2024:1-17.
10. Jung C, Abdelaziz Mahmoud NS, Al Qassimi N, Elsamanoudy G. Preliminary Study on the Emission Dynamics of TVOC and Formaldehyde in Homes with Eco-Friendly Materials: Beyond Green Building. J Buildings. 2023;13(11):2847.
11. Shao L, Li J, Zhao H, Yang S, Li H, Li W, et al. Associations between particle physicochemical characteristics and oxidative capacity: an indoor PM10 study in Beijing, China. J Atmospheric Environment. 2007;41(26):5316-26.
12. Li J, Liang F, Liu F, Li J, Huang K, Yang X, et al. Genetic risk modifies the effect of long-term fine particulate matter exposure on coronary artery disease. J Environment International. 2022;170:107624.
13. Rösch C, Kohajda T, Röder S, von Bergen M, Schlink U. Relationship between sources and patterns of VOCs in indoor air. J Atmospheric Pollution Research. 2014;5(1):129-37.
14. Semple S, Garden C, Coggins M, Galea K, Whelan P, Cowie H, et al. Contribution of solid fuel, gas combustion, or tobacco smoke to indoor air pollutant concentrations in Irish and Scottish homes. J Indoor air. 2012;22(3):212-23.
15. Jo W-J, Sohn J-Y. The effect of environmental and structural factors on indoor air quality of apartments in Korea. J Building Environment. 2009;44(9):1794-802.
16. Zhao H, Chan WR, Cohn S, Delp WW, Walker IS, Singer BC. Indoor air quality in new and renovated low‐income apartments with mechanical ventilation and natural gas cooking in California. J Indoor air. 2021;31(3):717-29.
17. Yoon C, Lee K, Park D. Indoor air quality differences between urban and rural preschools in Korea. J Environmental Science Pollution Research. 2011;18:333-45.
18. Datta A, Suresh R, Gupta A, Singh D, Kulshrestha P. Indoor air quality of non-residential urban buildings in Delhi, India. J International Journal of Sustainable Built Environment. 2017;6(2):412-20.
19. Chithra V, Nagendra SS. Indoor air quality investigations in a naturally ventilated school building located close to an urban roadway in Chennai, India. J Building Environment 2012;54:159-67.
20. Gamal A, Hidayat HY, Maharani IGAAK, Wangkanusa MN, Budihardjo B, Alhamid MI, et al. Indoor air quality control at national-level regulations: A special case in Indonesia. J Journal of Air Pollution Health. 2023;8(3):315-38.
21. Dimitroulopoulou S, Dudzińska MR, Gunnarsen L, Hägerhed L, Maula H, Visualisation RS, et al. Indoor air quality guidelines from across the world: An appraisal considering energy saving, health, productivity, and comfort. J Environment International. 2023:108127.
22. Wei G, Yu X, Fang L, Wang Q, Tanaka T, Amano K, et al. A review and comparison of the indoor air quality requirements in selected building standards and certifications. J Building Environment. 2022;226:109709.
23. Goldstein L, Dewhirst M, Repacholi M, Kheifets L. Summary, conclusions and recommendations: adverse temperature levels in the human body. International Journal of Hyperthermia 2003;19(3):373-84.
24. Drinker CK. The Effects of Heat and Humidity upon the Human Body. Journal of Industrial Hygiene Toxicology 1936;18:471-85.
25. Stewart RD. The effect of carbon monoxide on humans. J Annual review of pharmacology 1975;15(1):409-23.
26. Sosa BS, Porta A, Lerner JEC, Noriega RB, Massolo L. Human health risk due to variations in PM10-PM2.5 and associated PAHs levels. J Atmospheric environment 2017;160:27-35.
27. Zhang Z-F, Zhang X, Zhang X-m, Liu L-Y, Li Y-F, Sun W. Indoor occurrence and health risk of formaldehyde, toluene, xylene and total volatile organic compounds derived from an extensive monitoring campaign in Harbin, a megacity of China. J Chemosphere 2020;250:126324.
28. Heseltine E, Rosen J. WHO guidelines for indoor air quality: dampness and mould. 2009.
29. Khan AA, Garsa K, Jindal P, Devara P, Tiwari S, Sharma P. Demographic Evaluation and Parametric Assessment of Air Pollutants over Delhi NCR. J Atmosphere. 2023;14(9):1390.
Files
IssueVol 9 No 3 (2024): Summer 2024 QRcode
SectionOriginal Research
DOI https://doi.org/10.18502/japh.v9i3.16681
Keywords
Indoor air quality; Particulate matter; Total volatile organic compounds; Formaldehyde; Temperature and humidity

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Kalia S, Mishra N, Ghose P. Indoor air quality assessment of an existing apartment located in Indian tropical city, Bhubaneswar. JAPH. 2024;9(3):383-402.