Original Research

Indoor air quality in wards of dental school clinic: Variations of VOCs, CO2 and airborne particle levels

Abstract

Introduction: The indoor environment of dental clinics may endanger dental patients and personnel and due to a great variety of air pollutants throughout the usual dental operation. The purpose of the present cross-sectional study was the evaluation of Indoor Air Quality (IAQ) and factors affecting it in a dentistry faculty of Arak University of Medical Sciences.
Material and methods: The IAQ of five dental active wards and the patient waiting room was evaluated. The concentrations of Total Volatile Organic Compounds (TVOC), CO2, particulate matter, and bioaerosols were measured.
Results: The TVOCs concentration in sampling locations ranged between 817 to 3670 μg/m3 during dental work and exceeded the Leadership in Energy and Environmental Design (LEED) guideline in all sampling locations. The highest values of Particulate Matter (PM) for PM10, PM2.5, and PM1 were observed in the periodontics ward, while the lowest values were observed in the endodontics ward. The PM2.5 concentrations exceeded the WHO limit in periodontics and pediatric wards. TVOC levels had a significant positive correlation with temperature (r=0.374, p<0.01) and RH (r=0.265, p<0.05). The predominant bacterial genus of the patient waiting area was Bacillus (36%), while the dominant bacterial genus of the other sampling site was Micrococcus spp. Penicillium (35.5%) and Cladosporium (28%) were the predominant fungi detected.
Conclusion: Controlling of airborne particles is to be standardized by the infection control actions of dental clinics and improved ventilation capacity in the air conditioning system was suggested for reducing VOCs and PM concentrations.

1. Cincinelli A, Martellini T. Indoor air
quality and health. International Journal of
Environmental Research and Public Health.
2017;14(11):1286. https://doi.org/10.3390/
ijerph14111286.
2. Cocârţă DM, Prodana M, Demetrescu
I, Lungu PEM, Didilescu AC. Indoor
Air Pollution with Fine Particles and
Implications for Workers’ Health in Dental
Offices: A Brief Review. Sustainability.
2021;13(2):599. https://doi.org/10.3390/
su13020599.
3. Szymanska J. Dental bioaerosol as
an occupational hazard in a dentist’s
workplace. Annals of Agricultural and
Environmental Medicine. 2007;14(2).
4. Mirhoseini SH, Koolivand A, Bayani
M, Sarlak H, Moradzadeh R, Ghamari F,
Sheykhan A. Quantitative and qualitative
assessment of microbial aerosols in different
indoor environments of a dental school
clinic. Aerobiologia. 2021 Jun;37(2):217-
24. https://doi.org/10.1007/s10453-020-
09679-z
5. Helmis CG, Tzoutzas J, Flocas HA, Halios
CH, Assimakopoulos VD, Stathopoulou OI,
Panis V, Apostolatou M. Emissions of total
volatile organic compounds and indoor
environment assessment in dental clinics
in Athens, Greece. International dental
journal. 2008 Oct;58(5):269-78.
6. Bazzazpour S, Rahmatinia M, Mohebbi
SR, Hadei M, Shahsavani A, Hopke
PK, Houshmand B, Raeisi A, Jafari AJ,
Yarahmadi M, Farhadi M. The detection of
SARS-CoV-2 RNA in indoor air of dental
clinics during the COVID-19 pandemic.
Environmental Science and Pollution
Research. 2021 Aug 3:1-9.
7. Hong Y-J, Huang Y-C, Lee I-L, Chiang
C-M, Lin C, Jeng HA. Assessment
of volatile organic compounds and
particulate matter in a dental clinic and
health risks to clinic personnel. Journal
of Environmental Science and Health Part
A. 2015; 50(12):1205–14. https://doi.org/
10.1080/10934529.2015.1055129
8. Mirhoseini SH, Didehdar M, Akbari M,
Moradzadeh R, Jamshidi R, Torabi S. Indoor
exposure to airborne bacteria and fungi in
sensitive wards of an academic pediatric
hospital. Aerobiologia. 2020;1–8. https://
doi.org/10.1007/s10453-020-09624-0
9. ASHRAE. Standard 62.1-2016 for the
Ventilation for Acceptable Indoor Air
Quality. 2016.
10. D. LEED v4 for Building Design and
Construction. U.S. Green Building Council:
Washington, DC, USA. 2019.
11. WHO Air quality guidelines: global
update 2005: particulate matter, ozone,
nitrogen dioxide, and sulfur dioxide. World
Health Organization. 2006.
12. Vu LM. Pilot study assessment of
indoor air quality in two dental settings:
Particulate matter and volatile organic
compounds. Dissertation, University of
Texas School of Public Health 2011.
13. Helmis CG, Tzoutzas J, Flocas HA, Halios
CH, Stathopoulou OI, Assimakopoulos
VD, Panis V, Apostolatou M, Sgouros G,
Adam E. Indoor air quality in a dentistry
clinic. Science of the Total Environment.
2007 May 15;377(2-3):349-65. https://doi.
org/10.1016/j.scitotenv.2007.01.100
14. Liu M-H, Tung T-H, Chung F-F, Chuang
L-C, Wan G-H. High total volatile organic
compounds pollution in a hospital dental
department. Environmenal Monitoring and
Assessessment. 2017;189(11):571. https://
doi.org/10.1007/s10661-017-6265-z.
15. Godwin CC, Batterman SA, Sahni SP,
Peng C-Y. Indoor environment quality in
dental clinics: potential concerns from
particulate matter. American Journal of
Dentistry. 2003;16(4):260–6.
16. Santarsiero A, Fuselli S, De Blasio G,
De Felice M, Nazzicone M, Ortolani E.
Dentistry setting and related environment:
a preliminary study. Annali di igiene:
medicina preventiva e di comunita
2007;19(6):541–50.
17. Zemouri C, Awad SF, Volgenant CMC,
Crielaard W, Laheij A, De Soet JJ. Modeling
of the transmission of coronaviruses, measles
virus, influenza virus, Mycobacterium
tuberculosis, and Legionella pneumophila
in dental clinics. Journal of dental
research. 2020;99(10):1192–8.https://doi.
org/10.1177/0022034520940288
18. Peng Z, Jimenez J. Exhaled CO2 as a
COVID-19 infection risk proxy for different
indoor environments and activities.
Environmental Science & Technology
Letters. 2021;8,5:392–397. https://doi.
org/10.1021/acs.estlett.1c00183.
19. Polednik B. Aerosol and bioaerosol
particles in a dental office. Environmental
Research. 2014; 134:405–9. https://doi.
org/10.1016/j.envres 2014.06.027
20. Rexhepi I, Mangifesta R, Santilli M,
Guri S, Di Carlo P, D’Addazio G, Caputi
S, Sinjari B. Effects of natural ventilation
and saliva standard ejectors during the
COVID-19 pandemic: A quantitative
analysis of aerosol produced during
dental procedures. International Journal
of Environmental Research and Public
Health. 2021 Jan;18(14):7472. https://doi.
org/10.3390/ijerph18147472
21. Kadaifciler DG, Cotuk A. Microbial
contamination of dental unit waterlines
and effect on quality of indoor air.
Environmental Monitoring and
Assessessment. 2014;186(6):3431–44.
https://doi.org/10.1007/s10661-014-3628-6.
Files
IssueVol 6 No 3 (2021): Summer 2021 QRcode
SectionOriginal Research
DOI https://doi.org/10.18502/japh.v6i3.8230
Keywords
Indoor air quality; Dentistry; Volatile organic compounds (VOCs); Airborne particle; Bioaerosol

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
How to Cite
1.
Bayani M, Mirhoseini SH, Koolivand A, Sarlak H, Moradzadeh R, Ghamari F, Sheykhan A, Taheri A. Indoor air quality in wards of dental school clinic: Variations of VOCs, CO2 and airborne particle levels. JAPH. 2022;6(3):171-180.